Covid-19 PCR Testing - Lepu Medical Solution
SARS-CoV-2 Nucleic Acid Test
PCR-Fluorescence Probe method
Quotation & Pricing: eu@genprice.com
SARS-CoV-2 Nucleic Acid Test Kit is a real-time RT-PCR test intended for the qualitative detection in ORF1ab and N genes of SARS-CoV-2 viral nucleic acids in pharyngeal specimens (oropharyngeal swabs, nasopharyngeal swabs) from individuals who are suspected of COVID-19 by their healthcare provider.
|
Product Specifications
Number of Tests / Kit : 24 tests
Sample Type : Oropharyngeal swabs, Nasopharyngeal swabs Acceptable Real-time PCR System : LEPU Lepgen-96, Roche LightCycler 480 series, Bio-Rad CFX96 Reagent Preparation Condition : 4 weeks at 2°C ~ 8°C Reagent Storage Condition : 6 months at -25°C ~ -15°C. The freeze/thaw cycles should not exceed five times |
Key Components
CoV-PCR Reaction Liquid (Qty 1) (460µl/vial) ORF1ab and N genes primer and probe, Internal control RNaseP gene primer and probe, Deoxyribonucleoside triphosphate.
CoV-enzyme (Qty 1) (24µl/vial) DNA polymerase, Reverse transcriptase, Recombinant RNase inhibitor. CoV-Negative Control (Qty 1) (420µl/vial) DEPC treated water. CoV-Positive Control (Qty 1) (420µl/vial) ORF1ab and N genes, RNaseP gene armored RNA solution |
LepGen-96 Real Time qPCR
Quotation & Pricing: eu@genprice.com
Capacity :
Applied probe:
Thermal cycle temperature control : Semiconductor thermoelectric module. Temperature Range : 4.0°C - 99.0°C Heating & Cooling Rate : ⩾1.5°C/sec Thermal Accuracy : ⩽0.5°C (at 90°C) Thermal Uniformity : ⩽0.5°C (at 90°C) Hot cover temperature range : 50°C - 108°C Optical detection excitation wavelength : 300-800 nm Detection wavelenght: 500-800 nm Fluorescence repatability : ⩽3% Fluorescent linearity : r⩾0.99 coefficient of correlation |
Software application : genotyping by qualitative, absolute quantitative, standard solution curve relative quantitative and end point method.
Scanning method : Full plate, specified rank scanning Data Export format : Excel, CSV Custom report form : support The operating system : Windows 7/8/8.1/10 Minimum computer configuration : Intel or AMD Dual-2.8GHz, more than 4G memory and 128GB Power supply : AC 220V, 50Hz, <800VA Communication Ports : RS232, USB Size : 490mm x 355mm x 284mm Weight : 20 Kg |
Nucleic Acid Extraction or Purification Kit
Quotation & Pricing: eu@genprice.com
Size: 96 Tests/Kit
Model :
Main Components
|
Size: 50 Tests/Kit (Manually)
Main Components
|
Nucleic Acid Extraction System
Quotation & Pricing: eu@genprice.com